Gate Safety for Hinged Gates

In recent months unsafe installations of Sliding Gates by other manufacturers have caused accidents resulting in tragic fatalities. However all automated gates, whether sliding, hinged or bi-folding should be installed with the correct safety devices. At Frontier Pitts, we highly recommend the following safety features are fitted to your hinged gate, to ensure that the gate is installed and operated in accordance with the Workplace (Health, Safety and Welfare) Regulations 1992, BS EN 12453:2001 and BS EN 12445:2001, to alleviate the dangers associated with automated hinged gates.

Health and Safety Options

In accordance with the Workplace (Health, Safety and Welfare) Regulations 1992, BS EN 12453:2001 and BS EN 12445:2001
it is highly recommended that the following items are fitted to your gate.
Other applicable BS standards:

·  EN 12453 Industrial doors and gates; Safety in use of power operated doors - requirements
·  EN 12445 Industrial doors and gates; Safety in use of power operated doors - Test Methods
·  EN 12604 Industrial doors and gates; Mechanical Aspects - Requirement
·  EN 12605 Industrial doors and gates; Mechanical Aspects - Test Methods
·  EN 60204-1 Safety of Machinery - Electrical Equipment of Machines

For Sliding Gate Safety, please click here
For Bi-folding Gate Safety, please click here

hingedgateds
To Download
Hinged Gate
Safety Datasheet,
please click here

hse

pyw

 

 

 

 

d

 

 

 

 

 

 

 

 

 

 

gate safety
gate safety

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

safety edge

1. Warning - Edge of gateleaf. Safety Edges should be fitted to the hinged gates closing vertical leading edge
of the gateleaf for closing safety. Additional safety edges can be mounted to the bottom beam for opening
& closing safety. Safety edges are flexible strips which are fixed to the edge of a gate where there is a risk of
a crushing or shearing hazard, preventing the gate closing on a person or vehicle in the event the gate is
activated. If the safety edge is depressed a signal is sent to the power source to stop. *

* This is dependent on actuator model & control board
sliding gate motor

2. Electrical Warning - Awareness needs to be given to the Automatic Hinged Gate’s Control Cabinet

loop
3. Warning - Vehicle Detector Safety Induction Loops - loops cut into the road surface. This will prevent the
gate from closing on a vehicle within the aperture.
photocells

4. Warning - Safety Photocells. An infra-beam which spans the aperture of the gate opening. If an object
breaks this beam, the gates will stop & reverse. Photocells are fitted on the insecure side of the gate for
closing safety & the secure side for opening safety.

flashing beacon
5. Warning - Audible alarm and/or flashing beacon required to provide an audible or visible warning that
the gate is in operation.
weldmesh

6. No Pedestrian Access - Pedestrians should not put their limbs through the bars of the gate. This safety
feature is more applicable to sliding gates, however hinged gates may require weldmesh infill (clipped to
the gates infill bars) depending on the layout and requirements of individual sites.

run back

7. Warning - Awareness of potential trapping points - Pedestrian Guard Rail (fence panels) and/or signage
can be installed to prevent/warn pedestrians accessing the area where the Hinged Gate leaf will be opening
and closing.